X

Use code RAM23 at checkout to save 15% on all detectors during Radon Action Month.

 

  • Skip to main content
  • Skip to secondary menu
  • Skip to footer
  • America
    • International/English
    • Sweden/Sverige/svenska
    • United Kingdom/English
    • Norway/Norge/norsk
    • Germany/Deutschland/Deutch
    • Denmark/Danmark/dansk
    • France/France/Français
    • Spain/España/Español
  • Free & Fast Delivery | Ships Same Day*
  • News
  • About Us
  • Contact us
  • My Pages: View Your Results

Radonova

Radonova has some of the most accurate radon test kits available anywhere. Our radon test kits are available for both short term and long term test kits.

  • Home
  • Radon Test Kits
    • Long Term Kits – Radtrak³

      MOST ACCURATE | 90+ Days

    • Short Term Kits – Rapidos

      ACCURATE | 10 – 90 Days

    • Radon Screening – QuickScreen

      FASTEST | 48 – 96 Hours

    • Compare Tests
    • Daycare Tests
    • Digital Home Measurement
  • Radon Gas Test Kits
  • Commercial Solutions
    • Commercial Solutions
    • Radon Instruments
    • Bulk Test Kits
    • QuickScreen
      • Kits
      • Detectors
    • Rapidos
      • Kits
      • Detectors
    • Radtrak³
      • Kits
      • Detectors
    • Personal Radon Dosimetry
  • Resources
  • Shop
  • Long Term Kits – Radtrak³

    MOST ACCURATE | 90+ Days

  • Short Term Kits – Rapidos

    ACCURATE | 10 – 90 Days

  • Radon Screening – QuickScreen

    FASTEST | 48 – 96 Hours

  • Compare Tests
  • Digital Home Measurement
  • RESOURCES

    FAQs ABOUT RADON & TESTING

  • My Pages: View Your Results
  • About Us
  • Government Solutions
  • Contact us
  • Search
  • Home
  • Radon Test Kits
    • Long Term Kits - Radtrak³MOST ACCURATE | 90+ Days
    • Short Term Kits - RapidosACCURATE | 10 – 90 Days
    • Radon Screening - QuickScreenFASTEST | 48 – 96 Hours
    • Compare Tests
    • Daycare Tests
    • Digital Home Measurement
  • Radon Gas Test Kits
  • Commercial Solutions
    • Commercial Solutions
    • Radon Instruments
    • Bulk Test Kits
    • QuickScreen
      • Kits
      • Detectors
    • Rapidos
      • Kits
      • Detectors
    • Radtrak³
      • Kits
      • Detectors
    • Personal Radon Dosimetry
  • Resources
  • Shop
  • Long Term Kits - Radtrak³MOST ACCURATE | 90+ Days
  • Short Term Kits - RapidosACCURATE | 10 – 90 Days
  • Radon Screening - QuickScreenFASTEST | 48 – 96 Hours
  • Compare Tests
  • Digital Home Measurement
  • RESOURCESFAQs ABOUT RADON & TESTING
  • My Pages: View Your Results
  • About Us
  • Government Solutions
  • Contact us
  • Search

Radonova’s Newest Product – Robin

By Steve | May 8, 2019 Leave a Comment Radonova News

Earlier in the year, Radonova took the strategic decision to broaden its range of radon measurement technologies by adding several advanced instruments and products to its portfolio via the acquisition of the radon measurement instrument division of Gammadata Instruments.

Here we take a more in-depth look at ROBIN, one of the state-of-the-art radon monitors developed and manufactured by Gammadata, which is compact, light and suitable for all types of ventilation control facilities where there is a need to monitor radon levels.

Industrial ROBIN

Renowned for its stability and rugged aluminium design, ROBIN is an industrial radon sensor for ventilation applications such as air handling units, roof fans and radon evacuation fans. For industrial radon detection, there are two versions of ROBIN offering different measurement ranges: 0-400Bq/m3 and 0-4000Bq/m3. Each unit is factory calibrated with traceable industry standards.

ROBIN measures radon air levels and converts the concentration to an accurate output signal. The sensor can be connected to a fan controller, PLC or any other analog input signal device.

The sensor has high immunity to EMC and can withstand interference from thyristor controllers. The radon sensor can be deployed as a fixed installation and is placed in ventilation ducts, air handling units or just in a room. Due to its design, ROBIN functions independently of air flow conditions and can measure accurately in both laminar and turbulent airflow.

Technical Specifications for ROBIN 0-400 Bq/m³ and ROBIN 0-4000 Bq/m³:

Measurement principle: Filtered diffusion to high voltage measurement chamber
Detection principle: Alpha spectrometry
Output signal: 1-10 V
Measurement range: 0-4000 Bq/m³
Maximum measurement range: 0 – 100000 Bq/m³
Accuracy: Typically within 25% @ 200 Bq/m³
Time resolution: From 1 h
Connection: 4-pole connector block
Weight: 240 g
Dimension:  Length 60 x Width 76 x Height 45 [mm]
Power supply: 12 V DC or 10 – 30V AC/DSDC(two models).
Power consumption: < 50 mW
Temperature Storage: 0 – 70
⁰C
Temperature Operation: 0 – 60
⁰C

ROBIN in Mining

For the mining industry, a reinforced version of ROBIN is available for fixed installations in underground environments. The mining version of ROBIN measures the radon in air and converts the concentration to a proportional output signal.

The default measurement range is 0-4000 Bq/m³, but this can be easily customized on request. As with other versions of ROBIN, the radon sensor has a high immunity to EMC. Protection against humidity is achieved by additional painting on the PCB and the provision of a thermal load in close proximity to the detector which duly prevents condensation.

Technical Specifications:

Measurement principle: Filtered diffusion to high voltage measurement chamber
Detection principle: Alpha spectrometry
Output signal: 1-10 V
Measurement range: 0-4000 Bq/m³. Range is customizable.
Maximum measurement range: 0 – 100000 Bq/m³
Uncertainty: Typically within 25% @ 200 Bq/m³
Time resolution: From 1 h
Cable gland: M20
Connector: Shielded Cable with 4 leads. Internally to 4-pole connection block.
Weight: 240g
Dimension: Length 80 x Width 76 x Height 45 [mm]
Power supply: 10 – 30 V AC or DC
Power consumption: 60 mA at 24V
Temperature Storage: 0 – 70
⁰C
Temperature Operation: 0 – 60
⁰C
Humidity: Improved protection against humidity

For more information on radon and radon measurement visit www.radonova.com.
For more information, please contact Bill Rounds, President of Radonova
Phone: +1.331.814.2201, E-mail: bill.rounds@radonova.com

Previous Post
Next Post

About Steve

Reader Interactions

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Footer

Radonova | Radon Test Kits

Phone: 331.814.2200

QUESTIONS? CONTACT US

Return & Refund Policy
Privacy Policy
General Terms & Conditions

Applications

Residential

Commercial

Government

Products

Short Term Tests

Long Term Tests

Short Term Screening

Resources

FAQs

What causes Radon in basements?

How dangerous is radon?

Is radon only in Basements?

  • Twitter
  • Facebook
  • LinkedIn
  • YouTube
  • Instagram

Copyright © 2023 · radonova2019 On Genesis Framework · WordPress · Log in